Salient Features - High efficiency
- Fast response
- Wide input voltage range
- Audiable alarm for trip conditions
- 99.99% failure proof control circuit
- Built in digital volt/frequency meter
- No over under, shoots and hunting
- Built in bypass switch upto 100 Kva
- Sensing circuit is isolated from the mains
- Less active component avoids failure ratings
- Special electronic circuit to operate on gensets
- No effect of power factor and frequency variations
- Single PCB for three phase sensing and correction
- Automactic precision trip range settings at site without preset adjustment
- Voltage speed high torque dc servo motor proportionally controls corrections
- Rugged and smooth as motor drive control through optoisolator circuit which is highly reliable
High Reliability - High reliability due to digital and controlling using micro controller
- All components sourcedfrom reputed manufacturers, confirm to IS/BS/VDU standards
- All raw material inspection as per internal components manual
- Individual assemblies tested on full load at 55 deg c in oven for 48 hours to minimize failure
- Final equipment tested for accelerated life test to identify and replace any weak links.
Protections - Low voltage protections
- High voltage protections
- Phase rotation/single phasing preventer
- Input protection using HRC fuse
- Control circuit protection using fast blow fuse
Panel Control VAF / VF 3 Phase Model Start, Select, Stop / Reset Panel Indications - VAF 3 PH model : Input On, Output On, Input High, Input Low, Phase rotation fault, over load, cutoff
VF 3 PH model : Input On, Output On, Input High, Input Low, Phase rotation fault, cutoff
| | | PANEL METERS | | VAF 3 PH MODEL | | VF 3 PH MODEL | | Output Volts - R , Y, B, RY, YB & BR | | Output Volts - R , Y, B, RY, YB & BR | | Input Volts - R , Y, B, RY, YB & BR | | Input Volts - R , Y, B, RY, YB & BR | | Output Load Current : R, Y & B | | Output Set Voltage | | Output Set Voltage | | Sensitivity Adjustable From 2 - 9 Volts | | Sensitivity Adjustable From 2 - 9 Volts | | Frequency | | Over Load factory set as per unit | | | | Capacity frequency | | |
|
Product Specification |
Three Phase Oil Cooled
| 3,6,9,12,15,20,25,30,40,50,60 & 75 kva 100,125,150,200,250,300,400,500,750 & 1000 kva
| | Input voltage range | 170-270 single phase 295-465 volts three phase 195-270 single phase 340-465 volts three phase 205-270 single phase 360-465 volts three phase
| | Special range | As per customer requirements | | Output Voltage | 380/400/415 V AC in three phase | | System | Unbalanced / balanced type | | Connection | Star /Delta or Star / Star | | Output voltage regulation | (+/-) 1% from no load to full load | | Servo Motor drive model-A | AC servo synchronous motor | | Correction Speed | 35/V/sec-1 ph, 60 V/sec-3 ph | | Response Time | Above 60 milli.sec. | | Servo motor model-B | D.C. servo motor | | Correction speed | Upto 105 V/sec | | Response time | 10 milli sec. | | Operating frequency | 47 to 53 Hz | | Output waveform | True reproduction of input | | Insulation | Class "B" | | Short Circuit percentage and period | 300% for 250 milli sec. | | Overload Capacity | 120% for 1 minute | | Effect of load P.F. on OP Volts | Nil | | Waveform distortion | Nil | | Duty Cycle | 100% continuous | | Ambient | Zero to 45°cmax. Relative humidity upto 90% | | Type of cooling | Natural air cooled upto 75 kva, Natural oil cooled 3 to 1000 kva
| | System Construction | As per IS:9815 | | Enclosure | Powder Coated | | Efficiency | 98% (electrical consumption saved) | | Environment | Designed for indoor tropical use | | Mounting | On Wheels | | Earthing | Earthing terminals provided |
|
TOP |
Dimension
| (340V-465V Range) | L | W | H | Oil Capacity
| | 3Kva | 720 | 775
| 490
| 40 | | 6Kva | 1230 | 400
| 700
| 90
| | 9Kva | 1230 | 400 | 700
| 90
| | 12Kva | 1230 | 400 | 700 | 90 | | 15Kva | 1230 | 400 | 700 | 90 | | 20Kva | 1230
| 400 | 700 | 90
| | 22.5Kva | 1230 | 400 | 700 | 90
| | 25Kva | 1230 | 400 | 700 | 90
| | 30Kva | 1230 | 400 | 700 | 90 | | 40Kva | 1300 | 750 | 720 | 125 | | 50Kva | 1300 | 750 | 720 | 125 | | 60Kva | 1300 | 750 | 720 | 125 | | 75Kva | 1500 | 800 | 850 | 180 | | 100Kva | 1730 | 870 | 910 | 250 | | 125Kva | 1820 | 970 | 980 | 400 | | 150Kva | 1820 | 970 | 980 | 400 | | 200Kva | 2100 | 1050 | 1050 | 500 | | 250Kva | 2100 | 1050 | 1050 | 500 | | 300Kva | 2250 | 1050 | 1300 | 700 | | 350Kva | 2250 | 1050 | 1300 | 700 | | 400Kva | 2250 | 1200 | 1300 | 700 | | 500Kva | 2350 | 1200 | 1300 | 700 | | 750Kva | 2350 | 1200 | 2000 | 1200 | | 1000Kva | 2350 | 1200 | 2000 | 1200 |
| (295V-465V Range) | L | W | H | Oil Capacity
| | 3Kva | 720 | 775
| 490
| 40 | | 6Kva | 1230 | - -
| 700
| 90
| | 9Kva | 1230 | 400 | 700
| 90
| | 12Kva | 1230 | 400 | 700 | 90 | | 15Kva | 1230 | 400 | 700 | 90 | | 20Kva | 1300 | 750 | 720 | 125 | | 22.5Kva | 1300 | 750 | 720 | 125 | | 25Kva | 1300 | 750 | 720 | 125 | | 30Kva | 1300 | 750 | 720 | 125 | | 40Kva | 1300 | 750 | 720 | 125 | | 50Kva | 1500 | 800 | 850 | 180 | | 60Kva | 1500 | 800 | 850 | 180 | | 70Kva | 1500 | 800 | 850 | 180 | | 100Kva | 1730 | 870 | 910 | 250 | | 125Kva | 1820 | 970 | 980 | 400 | | 150Kva | 2100 | 1050 | 1050 | 500 | | 200Kva | 2100 | 1050 | 1050 | 500 | | 250Kva | 2250 | 1050 | 1300 | 700 | | 300Kva | 2250 | 1050 | 1300 | 700 | | 350Kva | 2250 | 1050 | 1300 | 700 | | 400Kva | 2250 | 1050 | 1300 | 700 | | 500Kva | 2250 | 1050 | 1300 | 700 | |
|